VACON Options Cards
VACON NX OPTIONS I/O cards | ||||||||||||||
PRODUCT CODE | Description | Suitability | ||||||||||||
OPT-A1 | 6DI, 1DO, 2AI(mA/V), 1AO(mA/V), +10 Vref, +24 V/EXT+24 V | NXS, NXP | ||||||||||||
OPT-A2 | 2RO(NO/NC) | NXS, NXP | ||||||||||||
OPT-A3 | 1RO(NO/NC), 1RO(NO), 1T1 | NXS, NXP | ||||||||||||
OPT-A4 | 3DI(Encoder RS422), Out +5 V/+15 V | NXP (NXS) | ||||||||||||
OPT-A5 | 3DI(Encoder 10...24V), Out +15 V/+24 V | NXP (NXS) | ||||||||||||
OPT-A7 | Double encoder (Wide Range), 6D1, 2xDO | NXP | ||||||||||||
OPT-A8 | As NXOPTA1, but analog I/O and +10Vref galv. de-coupled as a group | NXS, NXP | ||||||||||||
OPT-A9 | As NXOPTA1, but 2,5 mm² terminals, not with AF board | NXS, NXP | ||||||||||||
OPT-AA | 3DI, 1RO(NO/NC), 1DO | NXL | ||||||||||||
OPT-AE | Encoder board (Wide Range), 3DI(Encoder 10...24 V), Out +15 V/+24 V, 2DO (encoder divider and direction) | NXP (NXS) | ||||||||||||
OPT-AF-V | STO SIL2/PL"d" + ATEX appr. Thermistor, all boards need to be varnished | NXP | ||||||||||||
OPT-AI | I/O expander board for NXL, 3DI, 1RO (NO), Thermistor | NXL | ||||||||||||
OPT-AK-V | SIN/COS encoder interface | NXP | ||||||||||||
OPT-AL-V | 6DI (42…240VAC), 2AI, 2AO, 1DO, Out 15 V / 24 V | NXS, NXP | ||||||||||||
OPT-AN-V | 6DI galv. de-coupled as a group, 2AI and 2AO (Programmable 0…20mA, 4…20mA, 0…10V, 2…10V, -10…+10V) | NXP | ||||||||||||
OPT-B1 | 6DI/DO (programmable, DI or DO) | NXS, NXP, (NXL) | ||||||||||||
OPT-B2-V | 1RO(NO/NC), 1RO(NO), Thermistor | NX_ | ||||||||||||
OPT-B4-V | 1AI(mA, isolated), 2AO(mA, isolated), +24 V/EXT+24 V | NX_ | ||||||||||||
OPT-B5-V | 3RO(NO) | NX_ | ||||||||||||
OPT-B8-V | 3Pt100, +24 V/EXT+24 V | NXS, NXP (NXL) | ||||||||||||
OPT-B9 | 1RO(NO), 5 pcs of 41...240 VAC input | NXS, NXP (NXL) | ||||||||||||
OPT-BB | ENDAT encoder card, 2xDO (RS422) | NXP | ||||||||||||
OPT-BC | RESOLVER, 3x DO (Wide Range) | NXP | ||||||||||||
OPT-BE-V | SSI and Endat Encoders | NXP | ||||||||||||
OPT-BH-V | 3 x Temp sensor inputs (PT100, PT1000, KTY84-130, KTY84-150, KTY84-131, NI1000) | NXP | ||||||||||||
OPT-BL-V | Advanced safety option, requires AF board | NXP | ||||||||||||
OPT-BM-V | Advanced safety option - pulse encoder interface, requires AF board | NXP | ||||||||||||
OPT-BN-V | Advanced safety option - SIN/COS encoder interface, requires AF board | NXP | ||||||||||||
OPT-C2 | Modbus RTU / N2 | NX_ | ||||||||||||
OPT-C3-V | Profibus DP | NX_ | ||||||||||||
OPT-C4-V | LonWorks | NX_ | ||||||||||||
OPT-C5-V | Profibus DP (D9 type connector) | NX_ | ||||||||||||
OPT-C6 | CANopen | NX_ | ||||||||||||
OPT-C7-V | DeviceNet | NX_ | ||||||||||||
OPT-C8 | Modbus RTU / N2 (D9 type connector) | NX_ | ||||||||||||
OPT-CI-V | Modbus TCP/IP | NX_ | ||||||||||||
OPT-CJ-V | BACnet MS/TP | NX_ | ||||||||||||
OPT-CG-V | S2 Protocol | NXP | ||||||||||||
OPT-CP-V | ProfiNet I/O | NX_ | ||||||||||||
OPT-CQ-V | Ethernet/IP | NX | ||||||||||||
OPT-D1 | System Bus adapter (2x fiber optic cable, please find prices from previous page) | NXP | ||||||||||||
OPT-D2-V | System Bus (1x fiber optic cable, please find prices from previous page) & CAN-bus (galv. decoupled) | NXP | ||||||||||||
OPT-D3 | RS232 adapter card (not galvanically decoupled) | NXS, NXP | ||||||||||||
OPT-D6-V | CAN-Bus (galv. decoupled) | NXP | ||||||||||||
OPT-D7 | Line voltage measurement board | NXP | ||||||||||||
OPT-E9-V | 2-Port Ethernet option (Modbus TCP/UDP, PROFINET, EtherNet/IP, RSTP, MRP) | NXS, NXP | ||||||||||||
OPT-EC-V | EtherCAT field bus | NXP |
There are no products listed under this category.